Genset Perkins 300 kVA
Genset Perkins 300 kVA
Specifications
Power Output:
– Standby Power Rating: 300 kVA / 240 kW
– Prime Power Rating: 275 kVA / 220 kW
Engine:
– Model: Perkins 1104A-44TG1 or similar
– Governor: Electronic
– Speed: 1500 rpm
Alternator:
– Manufacturer: Leroy Somer or Stamford
– Voltage and Frequency:
– Voltage: 400V
– Frequency: 50Hz
Description
Genset Perkins 300 kVA
BELIALAT.COM support penjualan unit, parts, service, rental, maintenance contract, overhaul, reconditioned Genset Perkins 300 kVA
Specifications
Power Output:
– Standby Power Rating: 300 kVA / 240 kW
– Prime Power Rating: 275 kVA / 220 kW
Engine:
– Model: Perkins 1104A-44TG1 or similar
– Governor: Electronic
– Speed: 1500 rpm
Alternator:
– Manufacturer: Leroy Somer or Stamford
– Voltage and Frequency:
– Voltage: 400V
– Frequency: 50Hz
Control Panel:
– Model: Deep Sea DSE7320 or similar
Fuel Consumption:
– Approximately 45-65 liters per hour at 100% load (may vary depending on configuration)
Dimensions and Weight:
– Dimensions: approximately 1600 x 700 x 800 mm (may vary depending on configuration)
– Weight: approximately 800-1500 kg (may vary depending on configuration)
Fuel Tank Capacity:
– Varies depending on configuration (approximately 100-150 liters)
Noise Level:
– Varies depending on configuration (approximately 40-55 dB(A) at 7m)
Warranty:
– Varies depending on manufacturer and dealer (typically 1-2 years or 1000-2000 hours)
These specifications may vary depending on the configuration and application of the genset. It’s always best to consult the manufacturer or authorized dealer for the most accurate and up-to-date information.
Total Power
Gross Mechanical Output : 50-55 kW
Typical Electrical Output : 54-60 kVA (43-47kWe)
Rated Speed : 1500/1800 rpm
Emission Standards
Emissions : UN ECE R96 Stage IIIA constant speed and U.S. EPA Stationary Emergency Engine
50 Hz Typical Electrical Output
Prime : 40 kVA
Standby : 44 kVA
General
Number of Cylinders : 4 inline
Bore : 84 mm
Stroke : 100 mm
Displacement 2.2 Liters
Compression Ratio : 23.3:1
Aspiration : Turbocharged aftercooled
Combustion System : Indirect injection
Rotation from Flywheel End : Anti-clockwise
Cooling System : Liquid
Aftertreatment –
Typical Alternator Effeciency : 90%
Switchable : NO.
Electropak Dimensions
Dry Weight : 327 kg
Height : 985 mm
Length : 992 mm
Width : 602 mm
Disclaimer
Note 1 *Final dimensions dependent on selected options
Definitions
Prime Power : Power available at variable load in lieu of a main power network. Overload of 10% is permitted for one hour in every 12 hours of operation.
Standby Power : Power available at variable load in the event of a main power network failure. No overload is permitted.
Reviews
There are no reviews yet.